Calculating Required Sample Size based on Binomial
Recently a customer has begun experiencing rejections.  Out of a lot of 23,000 pieces they found 11 nonconformances after 100% inspection.  While this
... ANSI/ASQ Z1.4-2003 tables are calculated from binomial distribution. The probability to be wrong wh ...
http://www.isixsigma.com/ topic/ calculating-required-sample-size-based-on-binomial/ 67k cache

Sample size determination
Some plain speaking help is needed!My company issues contracts to all our customers every time they make a transaction with us. We have a customer complaints
... You can also use ANSI/ASQC Z1.4-1993.  The tables are the same as MIL-STD-105E, but the text is a ...
http://www.isixsigma.com/ topic/ sample-size-determination/ 80k cache

Calculations behind attribute sampling tables (SAE ARP9013/1)?
Can anyone point me to an explanation for the binomial, poisson and hypergeometric probability equations in relation to how they generate sampling tables (SAE
... to how they generate sampling tables (SAE ARP/9013/1, ANSI/ASQC Z1.4, and old MIL-105, etc.)? I wan ...
http://www.isixsigma.com/ topic/ calculations-behind-attribute-sampling-tables-sae-arp90131/ 70k cache

Sample Size Calculation for Attribute Data
Hi everyone! I am looking for some help on calculating sample size for attribute related data.  I am used to doing this for continous
... “Sampling Procedures and Tables for Inspection by Attributes”, ANSI/ASQ Z1.4-2003 Augus ...
http://www.isixsigma.com/ topic/ sample-size-calculation-for-attribute-data/ 86k cache

Acceptable Quality Level (AQL)
AQL is defined as the largest percentage of defectives that can make the lot definitely acceptable. I wonder why some of then sampling table have AQL
... ANSI/ASQC Standard Z1.4-1993 paragraph 4.1 This standard also says to interpret AQL in it’s t ...
http://www.isixsigma.com/ topic/ acceptable-quality-level-aql/ 64k cache

Sample Size Question
Can someone advise me on the appropriate formula for determining the sample size for the following problem:  An OEM supplier bonds two components together -
... and replaced by ANSI/ASQC Z1.4-1993, but in my experience it is till valid and widely used (plus Mi ... and widely used (plus Mil Std tables can be downloaded from several sites for free)Hope this helps, ...
http://www.isixsigma.com/ topic/ sample-size-question-7/ 74k cache

AQL – more than 100 in Sampling Plan Standards
While referring to the Standards available for Design of Sampling Plans for Attributes / Count of Defects, in the existing standards,  IS 2500 : Part 1
... of MIL-STD-105 or ANSI/ASQC Z1.4, look at the Operating Characteristic curves and tables for any g ... the standards. There are also tables/matrices for Average Outgoing Quality (AOQ) and Limiting Quali ...
http://www.isixsigma.com/ topic/ aql-more-than-100-in-sampling-plan-standards/ 101k cache

Attribute Inspection / ANSI Z1.4 / MIL Std 105E
I need some input if I am using the Subject standard correctly, in particular about the risk of acceptance. Taking one specific: For the normal inspection of
... select sample plan E.  From Table II-A, I understand that I should draw 13 samples for that sample ... plan.  For an AQL=10, if 4 or more of the samples are non-conforming then that lot should be labe ... not accept” ( ANSI Std. Z1.4, Section 6.1 phrase). Assuming the above is correct, on to my qu ...
http://www.isixsigma.com/ topic/ attribute-inspection-ansi-z1-4-mil-std-105e/ 62k cache

How to calculate area under curve
How to calculate area under curve? Please Help: In a normal distribution with mean 2.0 and standard deviation 0.05, what is the area under the curve between
... are not using March 7, 2007 at 4:15 pm #123020 Vidyadhar Include @Vidyadhar in your post and this p ... mean= 2.0 ; stdev0.05, Z1 =1.99  Z2 =2.10 For this u would have to look up at the Z table corresp ...
http://www.isixsigma.com/ topic/ how-to-calculate-area-under-curve/ 69k cache

MIL-STD 105D
Hi. I am unable to find the page or website for  MIL- STD 105D master table for : Table 11 -A single sampling plan Table 1 sample size code letters
... and then superseded by ANSI/ASQ Z1.4.  August 7, 2002 at 9:35 pm #31811 Ex MBB Include @Ex-MBB in ... intentionally designed the tables to ensure better protection for larger sixed lots.  If you have ...
http://www.isixsigma.com/ topic/ mil-std-105d/ 63k cache